Short answer: Ohm’s law says voltage equals current times resistance, E = I × R. Power is P = E × I, which also gives P = I² × R and P = E² ÷ R. In a series circuit the current is the same everywhere and the resistances add. In a parallel circuit the voltage is the same across every branch and the branch currents add. Most theory questions are one of these ideas plus careful arithmetic.
PSI lists electrical theory in two subject areas of the Texas Journeyman exam: Definitions, Theory and Plans has 3 scored NEC Knowledge questions, and Calculations and Theory has 2 scored Calculations questions. PSI does not say how many cover Ohm’s law alone, and the same formulas sit inside many other calculations. The Texas Journeyman Practice Pack has 1,000 original questions and 10 timed mock exams in the real two-part format, with step-by-step solutions for every calculation. Try free practice questions without signing up. Get the full pack for US$39 with one payment.
Tsai Electro is an independent learning site. Not affiliated with TDLR, PSI or NFPA. We explain the ideas in our own words. Check your work against your instructor’s method and follow your supervisor on the job.
The four formulas you use every day
| Find | Formula | Units |
|---|---|---|
| Voltage | E = I × R | volts |
| Current | I = E ÷ R | amperes |
| Resistance | R = E ÷ I | ohms |
| Power | P = E × I = I² × R = E² ÷ R | watts |
Pick the form that uses the two values the question gives you. If you know power and voltage, current is I = P ÷ E. If you know power and voltage and need resistance, R = E² ÷ P.
These formulas work directly for ideal resistive loads. Real heaters and incandescent lamps change resistance somewhat as they heat up. Motors, transformers and electronic loads add reactance and power factor, which the AC single-phase lesson covers.
Series circuits
In a series circuit there is one path for current.
- Current is the same through every part.
- Total resistance is the sum: R total = R1 + R2 + R3.
- Voltage drops add up to the source voltage. Each drop is I × R for that part.
- One open part stops the whole circuit.
Worked example. Three resistors of 10, 20 and 30 ohms are in series across 120 V.
- R total = 10 + 20 + 30 = 60 ohms.
- I = 120 ÷ 60 = 2 A, the same through each resistor.
- Drops: 2 × 10 = 20 V, 2 × 20 = 40 V, 2 × 30 = 60 V. They add to 120 V.
- Total power = 120 × 2 = 240 W.
Parallel circuits
In a parallel circuit each branch connects across the same two points.
- Voltage is the same across every branch.
- Branch currents add to the total current.
- Total resistance is less than the smallest branch. For two branches, R total = (R1 × R2) ÷ (R1 + R2).
- One open branch does not stop the others. That is why the receptacles and lights in a building are wired in parallel.
Worked example. A 20 ohm and a 30 ohm load are in parallel across 120 V.
- I1 = 120 ÷ 20 = 6 A. I2 = 120 ÷ 30 = 4 A.
- Total current = 6 + 4 = 10 A.
- R total = 120 ÷ 10 = 12 ohms. Check: (20 × 30) ÷ (20 + 30) = 600 ÷ 50 = 12 ohms.
- Total power = 120 × 10 = 1,200 W.
Kirchhoff’s voltage and current laws: two checks for DC practice
Use an ideal, steady-state DC paper model for these exercises. The two rules above, “drops add up to the source” and “branch currents add up to the total”, have names. First-year theory classes call them Kirchhoff’s laws, and they work in any DC resistive circuit, not only in simple series or simple parallel ones.
- Kirchhoff’s voltage law (KVL). Walk once around any closed loop. The voltage rises and drops you pass add to zero. Count the source as a rise (+) and each resistor drop in the direction of current as a drop (−).
- Kirchhoff’s current law (KCL). At any junction, the current flowing in equals the current flowing out. In these steady-state models, charge does not accumulate at a junction.
Worked example: a combination circuit. A 120 V source feeds R1 = 12 ohms in series with a parallel pair, R2 = 20 ohms and R3 = 30 ohms.
- Parallel pair: (20 × 30) ÷ (20 + 30) = 600 ÷ 50 = 12 ohms.
- Total resistance: 12 + 12 = 24 ohms. Total current: 120 ÷ 24 = 5 A.
- Drop across R1: 5 × 12 = 60 V. Voltage across the parallel pair: 5 × 12 = 60 V.
- Branch currents: I2 = 60 ÷ 20 = 3 A, I3 = 60 ÷ 30 = 2 A.
- KCL check at the junction where the pair splits: 5 A in, 3 A + 2 A = 5 A out.
- KVL check around the loop through R1 and R2: +120 − 60 − 60 = 0. The loop through R1 and R3 gives the same result because R2 and R3 share the same 60 V.
With unrounded values in this ideal example, both checks should balance. If they do not, recheck whether you added a parallel pair like series resistances or used total current instead of branch current for a drop.
Check yourself on Kirchhoff’s laws.
- A 24 V source feeds three resistors in series. Two of the drops are 9 V and 6 V. What is the third drop? 9 V, because 24 − 9 − 6 = 9.
- 12 A flows into a junction. One branch leaving it carries 7 A. What does the only other branch carry? 5 A, because 12 − 7 = 5.
- In the worked example, R1 is changed to 28 ohms. What is the total current, and do the branch currents still pass the KCL check? 40 ohms total, so 3 A. The pair has 36 V across it, giving 1.8 A and 1.2 A, which add to 3 A.
The practice above is free. For the existing beginner foundations, start with the free first-skill preview. The plan comparison explains the current options for saving foundation results and returning to checks that need review.
Examples of published first-year theory topics: CWC ELAP 1515 and BCIT Level 1 theory review.
Opens and shorts in a paper circuit: what changes and what stays
After solving the normal circuit, practise predicting what changes when a path opens or a resistor is bypassed. Use an ideal steady-state DC model for this paper exercise: the source holds 120 V, wires have zero resistance, an open has infinite resistance and an ideal bypass wire has zero resistance. Real fault behaviour depends on source and wiring impedance and on protective-device operation. These worked values belong to this model; they are not real fault-current predictions or a field-testing procedure.
- Series open (R1 here): the only path from the source is broken, so all current stops. The good resistors drop 0 V and the full source voltage appears across this series gap. The KVL check is +120 − 0 − 0 − 120 = 0.
- Resistor bypass (short): an ideal wire puts 0 V across the resistor or parallel pair it bypasses. In the two bypass cases below, total resistance falls and total current rises. Shorting across the parallel pair bypasses both resistors.
- Branch open (R3 here): the other branch still conducts. In this series-parallel example, total resistance rises and total current falls. The voltage across the remaining branch also changes; do not assume every load continues to operate normally.
Use the Kirchhoff worked example above: 120 V feeding R1 = 12 ohms in series with R2 = 20 ohms in parallel with R3 = 30 ohms.
| Condition | Total R | Total I | Across R1 | Across R2 and R3 | R2 / R3 current |
|---|---|---|---|---|---|
| Normal | 24 ohms | 5 A | 60 V | 60 V | 3 A / 2 A |
| R1 open | infinite | 0 A | 120 V across the gap | 0 V | 0 A / 0 A |
| R3 branch open | 12 + 20 = 32 ohms | 3.75 A | 45 V | 75 V | 3.75 A / 0 A |
| Short across R2 and R3 | 12 ohms | 10 A | 120 V | 0 V | 0 A / 0 A |
| Short across R1 | 12 ohms | 10 A | 0 V | 120 V | 6 A / 4 A |
For the cases in this table, an open in the series part drops the current to zero and puts the source voltage across the gap. Either resistor bypass shown here makes the total current rise. With the pair shorted, R1 dissipates 120 × 10 = 1,200 W instead of 60 × 5 = 300 W, four times its normal power. Every row still passes the KVL check: for the R3 open row, +120 − 45 − 75 = 0.
When the parallel pair is bypassed, its two resistors carry 0 A; the ideal bypass wire carries the full 10 A. When R1 is bypassed, R1 carries 0 A while its bypass wire carries 10 A. Keep resistor current and bypass-wire current separate.
Check yourself on opens and shorts.
- Two equal resistors are in series on 120 V, and one of them opens. What is the current, the voltage across the open, and the voltage across the good resistor? 0 A, 120 V and 0 V. With no current there is no drop across the good resistor, so the whole 120 V is across the open.
- In the worked example, the R2 branch opens instead. What are the total resistance and the total current? 12 + 30 = 42 ohms, so 120 ÷ 42 ≈ 2.86 A. R1 drops about 34.3 V and R3 about 85.7 V, which add to 120 V.
- In the worked example, R1 is shorted. What does each branch carry? The pair now has the full 120 V, so R2 carries 6 A and R3 carries 4 A, for 10 A total.
For a second explanation and circuit diagrams, see the ECStudioSystems textbook lesson on open and short circuits. The worked values above reuse this guide’s own 120 V circuit.
Worked example: a heater on the wrong voltage
A resistance heater is rated 4,800 W at 240 V. It is connected to 208 V. What is its output?
- Assume the element’s resistance stays constant for this calculation: R = 240² ÷ 4,800 = 57,600 ÷ 4,800 = 12 ohms.
- At 208 V: P = 208² ÷ 12 = 43,264 ÷ 12 = 3,605 W.
- Shortcut: power changes with the square of the voltage. (208 ÷ 240)² = 0.751, and 4,800 × 0.751 = about 3,605 W.
The voltage is about 13% lower, but the calculated power is about 25% lower. Exam questions that change the voltage on a resistive load usually expect you to hold resistance constant.
Mistakes that cost points
- Holding power constant when the voltage changes. For a constant-resistance load, power changes with the square of the voltage.
- Adding parallel resistances. Add currents in parallel, not resistances.
- Mixing kilowatts and watts. Convert to watts before you divide by volts. The prefix conversion table and examples show the same step for milliamps and kilohms.
- Using 120 V for a 240 V load. Read which voltage the load is connected across.
To check your numbers, use our Ohm’s law and power calculator and series and parallel calculator.
Check yourself
- A 1,500 W heater runs on 120 V. What current does it draw? 12.5 A, from I = P ÷ E.
- Two 10 ohm resistors are in parallel. What is the total resistance? 5 ohms.
- In a series circuit, which value is the same through every part? The current.
Disclosure: If you buy through the Amazon link below, Tsai Electro may earn a commission at no extra cost to you. As an Amazon Associate I earn from qualifying purchases.
Practice calculations with step-by-step lessons
Texas Journeyman Electrician Exam Prep 2026 NEC (paperback, 327 pages). 486 practice questions: 316 chapter questions across 20 chapters plus two full mock exams of 85 questions each, 59 NEC Knowledge in 130 minutes and 26 Calculations in 110 minutes. Includes calculation lessons and code lookup paths, and NEC questions come with article, section or table references.
FAQ
What is Ohm’s law in simple terms?
Voltage equals current times resistance. If you know any two of voltage, current and resistance, you can find the third.
What are the power formulas?
P = E × I, P = I² × R and P = E² ÷ R. All three give the same answer for a resistive load. Use the one that matches the values you have.
Why does a 240 V heater put out less heat on 208 V?
Assuming its resistance stays constant, power falls with the square of the voltage. A 4,800 W, 240 V heater gives about 3,605 W on 208 V.
Is Ohm’s law on the Texas Journeyman exam?
PSI lists electrical theory in Definitions, Theory and Plans (3 scored NEC Knowledge questions) and Calculations and Theory (2 scored Calculations questions). PSI does not say which formulas individual questions use, but these formulas are the base for load and conductor calculations.
Sources checked October 2026
- PSI Candidate Information Bulletin, Texas electrician examinations (updated September 15, 2026): https://test-takers.psiexams.com/api/content/bulletin/1682