Skip to main content
Not selected · English · Dual units
My account Join free Start free test
Home Texas Journeyman Calculation Check: 10 Worked Problems

Texas Journeyman Calculation Check: 10 Worked Problems

Try ten original calculation questions from our Texas Journeyman Electrician Exam Prep workbook (2026 NEC). Keep the conditions and units beside your working. Use 1.732 for √3 in this check.

You can check every answer and read the working without giving us an email address. The score summarizes these ten questions; it does not predict a licensing-exam result.

1. A single-phase load draws 10 amperes at 240 volts, and a wattmeter reads 1,920 watts. What is the power factor?
2. A 480Y/277-volt, three-phase feeder supplies only 50 kVA of lighting, balanced across the phases, and the lighting is a continuous load. The feeder overcurrent device is not part of an assembly listed for operation at 100% of its rating, and no other exception applies. Before rounding to a standard size, what is the minimum device rating?
3. Field-installed feeder tap conductors, not over 10 ft long, leave the enclosure in which the tap is made. The feeder is protected at 400 amperes, the tap ends in a 30-ampere circuit breaker, and the calculated load on the tap is 24 amperes. What minimum ampacity must the tap conductors have?
4. A feeder conductor has a base ampacity of 115 amperes. In an ambient temperature where the correction factor is 0.82, what is the corrected ampacity?
5. Six current-carrying conductors share a raceway, giving an adjustment factor of 0.80. If each conductor has a base ampacity of 130 amperes, what is the adjusted ampacity?
6. A feeder conductor with a base ampacity of 175 amperes is installed where the temperature correction factor is 0.88 and the conductor adjustment factor is 0.80. What is the final ampacity?
7. A single-phase feeder carries 80 amperes a one-way distance of 200 feet using conductors of 52,620 circular mils. Using K = 12.9 ohm-cmil/ft and VD = 2 x K x I x L / CM, what is the voltage drop?
8. A feeder operating at 240 volts has a voltage drop of 7.84 volts. What is the percentage of voltage drop?
9. A three-phase, 480-volt feeder supplies a balanced load of 120,000 VA. What is the feeder load in amperes?
10. A 120/240-volt, single-phase, 3-wire feeder supplies only linear line-to-neutral loads. One ungrounded conductor carries 90 amperes and the other carries 65 amperes, both at the same lagging power factor. What is the actual neutral current for these simultaneous loads?

These are study examples under the conditions shown. The NEC paths refer to the workbook’s 2026 edition. Actual installation decisions require all applicable conditions and local requirements.

Practise the next decision: compare limits and check your source

Build on the existing electrical study cases with two complete exercises. Work your own answer, compare the reasoning, then try the changed case.

Choose from a table only after checking both limits

How to approach it

Work from the load to the required comparison, then from the table to a choice. Keep the current criterion and the voltage-drop criterion in separate columns: satisfying one does not satisfy the other. This classroom dataset supplies its own loading multiplier, resistance model and limits. Its size labels A, B and C are paper options. Use the given 10 A operating current for the drop calculation; use 12.5 A for the separate current-capacity comparison. Writing both values down makes the reason for each step visible. A minimum-size question also requires checking that every smaller listed option fails at least one limit. If none passes, report no supported choice rather than extending the table from memory.

Work the case

A fictional 240 V, 2,400 W unity-power-factor load operates at a fixed 10 A for this exercise. The worksheet requires capacity of at least 1.25 times that current and a drop no greater than 6 V. At the supplied 100 m full path, option A is 11 A / 0.8 ohm, B is 15 A / 0.6 ohm and C is 20 A / 0.4 ohm. Capacities already include all adjustments specified for this worksheet. Choose the smallest listed option that meets both conditions. A note chooses A because 11 A exceeds 10 A. Diagnose the first wrong comparison.

  1. Write the operating current, required comparison current, and units before choosing a size.
  2. For each option, record capacity minus required current, drop, and whether both limits are met. Explain why each smaller option fails.
Compare your answer and first error

Operating I = 2,400 / 240 = 10 A. Required comparison current = 1.25 × 10 = 12.5 A. A: current margin −1.5 A and drop 10 × 0.8 = 8 V, so it fails both. B: margin +2.5 A and drop 6 V, so it meets both, including equality at the drop limit. C: margin +7.5 A and drop 4 V, so it also meets both but is not the smallest listed passing option. Choose B within this dataset. The first error in the note is comparing A with operating current instead of the separately required 12.5 A. Its second error is omitting the drop check. Keep the given, already-adjusted capacity separate from additional factors; do not apply the same adjustment twice.

Change the conditions. Try again.

Increase the full path to 150 m. Keep the operating current, capacity entries and drop limit unchanged. Resistance scales directly with full path length in the supplied model. Then test a second changed path of 200 m.

Check the changed case

At 150 m the resistance multiplier is 1.5: drops A/B/C are 12/9/6 V. Only C meets both conditions; choose C. At 200 m the drops are 16/12/8 V. None meets the 6 V limit, so the supported result is no listed option. Keep the unchanged current comparison at 12.5 A. Do not turn a no-option result into a guessed real conductor recommendation. For a later code-book exercise, replace the classroom limits only after identifying the adopted edition, applicable rule, actual table and task conditions with the responsible instructor.

Check your finished work

  • Both currents and their distinct uses are correct.
  • Every option has separate capacity and drop evidence, including the equality boundary.
  • The first error is identified and the minimum passing option is justified.
  • Both changed paths are recomputed; the no-option result is retained.
Find the supported reference path, then reopen it when the question changes

How to approach it

A useful lookup record preserves the source, its date, the edition discussed, the topic and the path supported by the provided text. A topic pointer gets you to the next place to read; it does not supply the detailed rule. Keep your first search phrase and the words you matched so another learner can repeat the search. When the task changes, start from its topic again instead of carrying over the old article number.

Work the case

Use only the two short source-card excerpts for the closed part of this exercise. A learner wants the 2026 topic path for branch-circuit, feeder and service load calculations. Write the edition, search terms, publisher/date and supported article-level path. A note says this pointer also proves a demand factor and conductor size, although neither appears in the excerpts. Identify the unsupported step. Then continue in your lawfully available edition-specific code book with an instructor: record the actual subsection or table, applicability conditions and what still needs checking; do not fill those fields by guessing.

Compare your answer and first error

Supported record: the two observed excerpts together support only a topic-level pointer to Article 120 for branch-circuit/feeder/service load calculations in the 2026 discussion. They do not form a single quoted rule that selects a demand factor, conductor size, subsection or table. topic = branch-circuit/feeder/service load calculations; edition discussed = 2026; publisher/date = NFPA Journal, April 29, 2025; article-level pointer = Article 120. Useful search terms include the topic and edition. The excerpts establish only that topic pointer. The demand factor, conductor selection and exact subsection/table are not supplied, so leave them pending until a direct edition-specific source supports them. A screenshot, page or locator from a different edition requires a new match. Record the actual source you consulted rather than treating this summary as the complete code.

Change the conditions. Try again.

The question now asks for motor full-load-current table selection. The same load-calculation source card is all that has been supplied. Can you reuse Article 120 as the answer? Write the next evidence request rather than inventing a motor-table number.

Check the changed case

No. The supplied excerpts do not identify a motor-current table. Reopen the lookup with the actual motor task, edition and intended use of the current. Request the applicable index entry and direct rule/table in that edition, then distinguish what each source supports. The correct closed-exercise result is insufficient supplied evidence for a motor-table path, with a concrete next-source request. A blank locator with a clear reason is more accurate than a confidently copied unrelated path.

Check your finished work

  • Publisher, date, edition and topic are recorded separately.
  • The closed answer matches the supplied Article 120 pointer.
  • The learner separates a topic pointer from an unprovided calculation rule.
  • The changed question triggers a new lookup and a specific evidence request.

Leer estos ejercicios en español

★ Resources
Scroll to Top
Not a licensed Professional Engineer in Texas or any U.S. state. Does not offer engineering services. Exam-prep education only.