Skip to main content
Not selected · English · Dual units
My account Join free Start free test
Home Texas Electrician Exams Texas Journeyman Exam Calculations: What Is Tested and How to Solve It

Texas Journeyman Exam Calculations: What Is Tested and How to Solve It

Texas journeyman exam calculations are a separate part of the test covering sizing and load problems from code tables and formulas. Practice by reading the question, identifying the needed table or rule, setting up the formula, then checking units and rounding. Use only references permitted by TDLR.

Short answer: The Calculations part of the Texas Journeyman Electrician exam has 26 questions (24 scored) in 110 minutes, and you need 70% to pass. It leans on branch circuits and conductors, services, feeders and special occupancies. In fiscal year 2025 only 20.56% of attempts passed, so build a repeatable method for each question type.

Part of Texas Electrician Exams: every Texas license step and exam in one place.

On this page

Contents

In detail: The Calculations part of the Texas Journeyman Electrician exam has 26 questions (24 scored) in 110 minutes, and you need 70% to pass. TDLR’s May 2026 staff report weights it toward branch-circuit calculations and conductors (4 points), services (4), feeders (3) and special occupancies (3). In fiscal year 2025 only 20.56% of attempts passed, and first-time takers averaged 13.15 of 24 points. The fix is a repeatable method for each question type plus fast lookups in your 2026 NEC.

Facts last checked October 1, 2026 against the PSI candidate information bulletin (updated September 15, 2026) and TDLR exam statistics. Code locations below are given as article numbers only. Confirm each one in your own 2026 NEC.

How the 24 scored points are split

Area (PSI outline)Scored points
Branch-circuit calculations and conductors4
Electrical services, service equipment, separately derived systems4
Electrical feeders3
Special occupancies, equipment and conditions3
Calculations and electrical theory2
Equipment and devices (appliances, A/C, heating)2
Wiring methods and materials (raceways, boxes)2
Motors and generators2
Control devices and disconnecting means1
Renewable energy (EV chargers, photovoltaics)1

Source: maximum topic scores in TDLR’s May 12, 2026 staff report, which add up to 24. You need about 17 correct to reach 70% (70% of 24 is 16.8).

Two bulletin rules that change your answers

  • Copper unless stated: treat every conductor as copper unless the question names aluminum.
  • No exceptions or optional methods unless asked: use the standard method, and apply a code exception or an optional calculation only when the question tells you to.

Many wrong answers on practice tests come from applying an optional method or exception that the question never mentioned.

Watch for the 2026 reorganization

Study material written for the 2023 NEC sends you to Article 220 for branch-circuit, feeder and service load calculations. In the 2026 NEC, those load calculations were reorganized into a new Article 120. If your notes, tabs or practice explanations cite 220, find the matching 2026 location before exam day. A question is only fast if you can open the book to the right page.

Five methods to have ready

1. Ohm’s law and power

Most theory points come from I = P / E and E = I × R. Example: a 1,500 W heater on 120 V draws 1,500 / 120 = 12.5 A. On 240 V the same heater draws 6.25 A. Write the formula before you start entering numbers, and check the units.

2. Continuous loads at 125%

For a load that runs 3 hours or more, size the overcurrent device and conductors for 125% of the continuous load plus 100% of the non-continuous load (the branch-circuit and feeder rules in Articles 210 and 215). Example: the 12.5 A heater running continuously needs 12.5 × 1.25 = 15.6 A, so a 15 A circuit is not enough.

3. Voltage drop

The common two-wire formula is VD = 2 × K × I × L / CM, where K is about 12.9 for copper, L is the one-way length in feet, and CM is the conductor area in circular mils from Chapter 9, Table 8. Example: 20 A over 100 ft on 12 AWG copper (6,530 cmil) gives 2 × 12.9 × 20 × 100 / 6,530 = 7.9 V, which is 6.6% of 120 V or 3.3% of 240 V. Our voltage drop calculator shows the same arithmetic. In the exam you calculate by hand with a non-programmable calculator.

4. Motor circuits use the table, not the nameplate

For motor branch-circuit conductors, take the full-load current from the NEC motor tables in Article 430, not from the nameplate, and size the conductors for at least 125% of that value. Example: if the table lists 28 A for the motor, the conductors need an ampacity of at least 35 A. The nameplate current is used for overload protection, a different step.

5. Box fill and conduit fill

Box fill (Article 314) is a counting exercise. Each conductor entering the box counts once, a device yoke counts twice, all equipment grounding conductors together count once, and internal cable clamps count once. Multiply the count by the volume allowance for the largest conductor and compare with the box volume. Conduit fill (Chapter 9, Table 1) limits the fill to 53% for one conductor, 31% for two and 40% for three or more. Annex C tables give the answer directly when all conductors are the same size.

How far first-time takers are from the line

In TDLR’s May 12, 2026 staff report, first-time takers averaged 13.15 of the 24 scored Calculations points, and repeat takers 13.75. Both are 3 to 4 points short of 16.8, the 70% line. Four more correct answers closes the gap, and the four heaviest areas above (branch circuits, services, feeders, special occupancies) hold 14 of the 24 points. For how those averages compare across years and exams, see Texas electrician exam pass rates.

A 3-week calculation plan

  1. Week 1: one method per day from the list above, 10 untimed problems each. Write the article and table you used next to every answer.
  2. Week 2: mixed sets of 13 problems in 55 minutes, half the real part at real pace.
  3. Week 3: two full timed Calculations parts (26 questions, 110 minutes). Review every miss by area, then redo it the next day without looking.

Keep a reproducible answer record

For every worked practice answer, retain the requested quantity, supplied inputs and units, reference edition and section if needed, formula or method, arithmetic, rounding instruction, and final reasonableness check. Mark an explanation incomplete when a required input or reference is missing.

Here is an original theory example with no code-table lookup: a 24 V DC source is applied to a stated 12 ohm ideal resistor. Current is I = V/R = 24/12 = 2 A. Power is P = VI = 24 × 2 = 48 W. A second check gives P = V squared/R = 576/12 = 48 W.

The repeated result checks the arithmetic in this model; it does not establish safety or permission for a physical installation. For a code-based answer, the record also needs the applicable 2026 NEC provision and its conditions, not just a formula.

Reproducible calculation practice

  1. TX-168: What is current in the supplied 24 V, 12 ohm ideal DC example?
    Answer: 2 A.
  2. TX-168: What power result do both supplied calculation paths produce?
    Answer: 48 W.
  3. TX-168: What makes a code-based explanation reproducible beyond its final number?
    Answer: Inputs, units, edition and exact reference, conditions, method, steps, rounding, and a check.

Official references checked October 16, 2026

Practice calculation questions

The free Texas Journeyman practice includes calculation questions with explanations, and there is no sign-up. The Texas Journeyman Practice Pack adds 10 timed Calculations parts in the PSI format and step-by-step solutions that show the rule used, every step, the rounding and why each wrong option is wrong. Every question is checked against the 2026 NEC text, and every correction is published with its date.

Next step on the Texas ladder

You are here: Exam calculations. Next: Code book tabs. Fast lookups in your 2026 NEC save time on both parts.

Also useful: Sample questions · All Texas electrician exams

Free first: try 70 Texas Journeyman practice questions in rounds of 20, no sign-up. Ready for full timed two-part mocks? See the practice pack: 1,000 questions and 10 mocks, one payment. See what’s inside.

A calculation review that shows where the mistake began

When an answer is wrong, rerunning the same arithmetic may repeat the same mistake. Use four short lines in your study notes:

  1. Given: List the supplied quantities and their units. Keep a value you assumed separate from one actually given in the question.
  2. Asked: Write the quantity and unit the question wants. Check that you are solving the requested problem before choosing a method.
  3. Method: Name the reference or relationship you are using and explain why it applies. Carry units through the arithmetic instead of attaching them only at the end.
  4. Check: Compare the result with the original question. If you change a unit or assumption, record that change so a later review can find it.

A simple unit example outside electrical work: 1.5 hours is 90 minutes. If your next step expects minutes but you enter 1.5, the problem began with the unit conversion, even if the later arithmetic was correct. This is a study-note example, not a live-work calculation.

Try the four-line review on one of the worked examples below, then on a different question. A correct repeated answer from memory is a weaker check than explaining a new example.

Related reading: Connect the method to an outline topic · Use the free practice entrance.

Choose learning support for the method you are practicing.

Use the worked examples to inspect your method, not just the final number. Compare paid ET Member plans if you want to choose a learning plan beyond this guide.

Review current paid-plan inclusions. Membership does not guarantee an exam result or replace professional judgment for real electrical work.

FAQ

How many calculation questions are on the Texas Journeyman exam?

26 questions, 2 of them unscored, in 110 minutes. You need 70% of the scored questions to pass this part, separately from the NEC Knowledge part.

What calculations are on the Texas Journeyman exam?

Branch-circuit and conductor sizing, service and feeder load calculations, special occupancies, motors, voltage drop and theory, box and raceway fill, appliances and heating loads, and EV chargers or photovoltaics.

Why is the calculations part so hard to pass?

Only 20.56% of attempts passed in TDLR fiscal year 2025. Each question takes several steps and one table lookup, and a single wrong assumption, such as an optional method, ruins the answer.

Can I use a calculator on the Texas electrician exam?

Yes, a silent, battery-operated, non-programmable calculator without paper tape and without an alphabet keyboard. Electronic notepads are provided at the test site.

Does the Texas exam assume copper or aluminum conductors?

Copper, unless the question specifically says otherwise. The PSI bulletin states this for both parts of the Journeyman exam.

Sources

About Tsai Electro

Tsai, creator of Tsai Electro, holds Taiwan’s national Class B Indoor Wiring Technician certificate. He worked on site on the MEP side of a smart temperature-controlled logistics center at Taipei Port, on the second-phase campus of Jiufenzi Junior and Elementary School in Tainan, and on the Liugui Administrative Center in Kaohsiung. The Liugui project was honored at the 25th Public Construction Golden Quality Awards. He teaches career switchers on YouTube @tsai.electro.

He writes these Texas guides from the official TDLR pages and the PSI candidate bulletin, cites NEC articles by number only, and dates every source. Found an error? Tell us and we will correct it.

Your next steps

  1. Find this step in the Texas career tree
  2. Compare ET Member plans
  3. See the practice or planning pack for this stage
★ Resources
Scroll to Top
Not a licensed Professional Engineer in Texas or any U.S. state. Does not offer engineering services. Exam-prep education only.